MULTIROOM TEMPERATURE CONTROLLER SYSTEMMULTIROOM TEMPERATURE CONTROLLER SYSTEMMULTIROOM TEMPERATURE CONTROLLER SYSTEM Up to 32 sensors per
10 7. Sensors setup ENGLISH Before the controller can work with the temperature sensors it must first scan the network for all connected sensors. If
11 Assign sensor names (can also be done using PC, advised) ENGLISH 1. Press and HOLD the ‘Menu’ button until the extended menu appears. 2. Scrol
12 8. operating the temperature controller Select room or zone Recall and change the desired temperature To set up a heating system for different ro
13 Setting the comfort, day and night temperature presets The temperature sensor VMB1TS can be used in 4 modes (comfort , day , night or
14 Start sleep timer or switch between preset modes ENGLISH The heating or (air-conditioning) can be forced temporary (sleep timer) into a certain mod
15 Setting the sleep time (temporary mode) ENGLISH Once the heating (or air-conditioning) is in temporary mode, the duration of the sleep timer can be
16 ENGLISH 9. Programming the controller This controller has two ways to program heating or cooling periods 1- Normal week timer programming (see next
17 Program step overview ↑ ↑ ↑ ↑ ENGLISH
18 Entering / changing a program instruction ENGLISH 1. Press the ‘Location’ button repeatedly until the room or zone of which a program instruction n
19 ENGLISH 7 8 9 10 ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ 7. Use the ↑ or ↓ button to set the time reference. Possibilities on which the instruction needs
There are several manuals available for this temperature control system: 1. Getting started manual, This guide can be found in the sensor package, a
20 Deleting a program instruction ENGLISH 1. Press the ‘Location’ button repeatedly until the room or zone of which the program instruction needs to
21 ENGLISH 10. Screen & LED indicators ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ Location Change room or zone. Push and hold to switch between rooms and zones. Exit the
22 ENGLISH 11. Controller menu overview User Remarks: 1. This menu is only accessible if the temporary mode (sleep timer) is activated 2. This menu is
VELLEMAN NV Legen Heirweg 33 9890 Gavere Belgium - Europe Modifications and typographical errors reserved - © Velleman nv. - HVMB1TC-UK - 2012 (rev
In this manual: 1. How to connect the temperature controller p.4 2. How to connect the temperature sensor p.5 3. Setting the address for sensor and
4 1. Temperature controller 'VMB1TC' connection Connection Battery backup To avoid losing the clock when a power failure occurs, a backup b
5 2. Temperature sensor 'VMB1TS' connection and button+indicators overview ENGLISH BUS TWISTED PAIR (0.5mm²) 14 15 8 9 1 2 3 4 5 6 7 10 11 1
6 ENGLISH 3. Address selection In order to identify each module in your system it is necessary to set an unique address for each module. This address
7 ENGLISH 4. Assign a relay channel to a temperature sensor function (can also be performed using PC, advised) On the sensor module: Set the sensor m
8 ENGLISH 5. Set the menu language on the controller 1. When applying power to the controller for the first time, only the time is shown on the disp
9 6. Setting the clock ENGLISH It is important to set the correct time for the internal clock. Setting the time on this module will synchronise all c