Velleman-projects HPS140 User manual Instrukcja Użytkownika Strona 4

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 28
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 3
- 4 -
Specifications & Features
40 Megasamples/s in real time
Bandwidth up to 10MHz
Full auto-range option
Sensitivity down to 0.1mV
Signal markers for amplitude and time
Memory ‘Hold’-function
Direct Audio Power Measurement (Watts)
USB battery charger included
X10 measuring probe included with HSP140i
Specifications:
Bandwidth: up to 10 MHz (-3dB or -4dB at selected ranges)
Input range: 1mV to 20V/division in 14 steps
Input coupling: DC, AC and GND
Real-time sample rate up to 40MS/s
AD resolution: 8 bits
Time base: 250ns to 1h per division
Auto set-up function (or manual)
Probe x10 readout option
x10 probe test signal on backside
Readouts: DC, AC+DC,True RMS, dBm, Vpp, Min-Max. (±2.5%)
Audio power measurement into 2 to 32 ohms
‘Hold’- & store function
Time and Voltage markers readout
Input : 100Vp AC+DC max.
White LED backlight
NiMH rechargeable battery pack (BPHPS140 included)
Operates up to 6 hours on a single charge
1
Charging power supply: 9Vdc/200mA
For use on CLASS II pollution degree II installations
Dimensions: 74x114x29mm ( 2.9x4.5x1.14)”
Weight: 200g, (7oz)
1
Do not operate the device while charging from the USB charger. Use a standard 9Vdc mains adaptor if opera-
tion during charging is required.